PRODUCTS

  • Product description
  • Specifications
  • Coating Thickness Gauge

     

    This compact gauge can be used for non-destructive coating thickness measurement of non-magnetic coatings,e.g . paint, enamel, chrome on steel,and insulating coatings,e. g. paint and anodizing coatings on non-ferrous metals.

     

    The internal probe can work on both principles,magnetic induction and the eddy Currents.The probe can automatically detect the substrates type(Magnetic or not),and calculate the coating thickness and display it fast.

    There are five data groups,and readings will be automatically storaged to memory for general groups(Not for direct group).Each group have individual statistics,alarm limit Settings and calibration. User can recall and delete specified readings easily.

    User do all operations via standard menu so easily. User can press the CAL button to Start multi-point calibration freely.

    Key words:
    • Coating Thickness Gauge
  • Name

    Probe F

    Probe N

    Measuring principle

    Magnetic induction

    Eddy Currents

    Measuring range

    0 to 1300um(0 to 51.2mils)

    0 to 1300um( 0 to 51.2mils)

    Accuracy

    ±(3%+1um)

    ±(3%+0.039mils)

    ±(3%+1um)

    ±(3%+0.039mils)

    Resolution

    0um~999(1um)

    1000um~1300um(0.01mm)

    0mils~39.39mils(0.01mils)

    39.4mils~51.2mils(0.1mils)

    0um~999um(1um)

    1000um~1300um(0.01mm)

    0mils~39.39mils(0.01mils)

    39.4mils~51.2mils(0.1mils)

    Calibration

    One point to four point calibration,

    zero point calibration,Basic

    Data group

    One direct group(readings not be stored to memory)

    Four general group(readings will be stored automatically)

    NOTE:each group have individual statistics,

    alarm limit settings and calibration

    Statistics

    No. of readings, mean, minimum,

    maximum and standard deviation

    Units

    um, mm, mils

    Alarm

    User can set the high/low alarm limit

    Alarm icon displayed on LCD when over the limit

    Minimum

    curvature

    radius convex

    1.5mm

    Minimum

    curvature

    radius concave

    2.5mm

    Minimum

     measuring area

    Diameter 6mm

    Minimum

    thickness or

    substrate

    0.5mm(0.02)”

    0.3mm(0.012)”

    Maximum

    measuring rate

    TWO readings per second

    Computer

    interface

    Download data via  USB

    Power supply

    TWO 1.5V AAA battery

    Operation

    environment

    Temperature:0 to 40℃(32 to 104F);

    humidity:20% to 90%rh

    Storage

    environment

    Temperature:-20 to 70℃(-4to 158F)

    Standard

    compliance

    ASTM B 499, ASTM D 1400, BS 3900-C5-6B,

    DIN 50981,DIN 50984,  ISO 1461,ISO 2360,

    Size

    110mmx53mmx24mm(4.33”x2.09”x0.94”)”

    Case Material

    ABS; 92g(3.24oz)

     

Send message
%{tishi_zhanwei}%