PRODUCTS

Portable X-ray Generator
Portable X-ray Generator
+
  • Portable X-ray Generator
  • Portable X-ray Generator

Portable X-ray Generator

  • Product description
  • Specifications
  • Portable X-ray Generator

     

    Frequency conversion air insulation portable X-ray generator can be widely used in

    shipbuilding, machinery manufacturing,aviation, rail, pressure vessels, boilers,

    oil, chemical, defense industry and other departments for non-destructive testing.

    Particularly applicable to construction site operation and high-altitude operations.

     

    1.Controller

    (1)The special design of high frequency technology can avoid the 

    interference by power spikes.Even though the voltage changes,it can still work.

    (2)All the signal wires in the controller are imported from South Korea to improve

    the  quality. 
    (3)Take the isolation technology of the low  voltage and the high voltage to ensure

    the controller working steady.

    (4)Posses the reliable "time-delayed" function, suitable to operate in the open field. 
    (5)High degree of automation with the function of trouble shooting and indication.

    (6)Controller adopts design of hardware with a wide operative range,having the   

    advantage of long service and low failure rate.

    (7)Strictly comply with 1:1 working/resting regulation,eliminating the disoperation.

     

    2.Generator

    (1)Safe and reliable generator adopts design of SF6 gaseous  insulator,

    grounded-anode,and air fan cooling.

    (2)High purity and high density aluminium radiator is specially designed for our  

    instrument.High temperature installation technology is adopted to improve 30%

    heat radiation.

    (3)The HV coils made by imported enamel wire are applied in the X-ray generator,

    so as to make the quality of the complete equipment improved a great deal.

    (4)The new technology can guarantee the machine to keep shooting for 30 minutes.

     

    3. Connecting Cable

    The length is 25m,much longer than the limited length by the international

    standard.It can guarantee the safety of the operator.

     

     

     

     

  • Classify

    Beam

    angle

     Model 

    No.

    Tube

     voltage

     (KV)

    Capacity

      (KW)

    Focus

     size

    (mm)

    Max.

    penetra-

    tion

     A3 steel

      (mm)

    X-ray

    generator   

    Size

    (mm)

    Weight

     (kg)

    Glass

    tube

    directional

     40°

    XXQ-

    P1005

    40-

    100

    >1.0

    1.0*1.0

    8

    180*180

    *540

    10

    XXQ-

    P1605

    60-

    160

    >1.5

    1.5*1.5

    20

    210*210

    *620

    15

    XXQ-

    P2005

    80-

    200

    >2.0

    1.5*1.5

    29

    290*290

    *680

    23

    XXQ-

    P2505

    130-

    250

    >2.5

    2.0*2.0

    39

    320*320

    *730

    35

    XXQ-

    P3005

    150-

    300

    >3.0

    2.5*2.5

    49

    340*340

    *850

    43

    XXQ-

    P3505

    200-

    350

    >3.5

    2.5*2.5

    59

    340*340

    *820

    42

     

    Glass

    tube

    panoramic

    with flat

    target

    360°

    *25°

    XXH-

    P1005

    40-

    100

    >1.0

    1.0*1.5

    6

    160*160

    *520

    11

    XXH-

    P1605

    60-

    160

    >1.5

    1.0*2.0

    18

    210*210

    *620

    15

    XXH-

    P2005

    80-

    200

    >2.0

    1.0*2.0

    26

    270*270

    *665

    20

    XXH-

    P2505

    130-

    250

    >2.5

    1.0*2.4

    36

    330*330

    *750

    32

    XXH-

    P3005

    150-

    300

    >3.0

    1.0*2.5

    46

    330*330

    *765

    41

    XXH-

    P3505

    200-

    350

    >3.5

    1.0*2.5

    56

    340*340

    *820

    42

     

    Glass

    tube

    panoramic

    with cone

    target

    360°

    *40°

    XXHA-

    P1605

    60-

    160

    >1.5

    1.0*3.5

    15

    210*210

    *620

    15

    XXHA-

    P2005

    80-

    200

    >2.0

    1.0*3.5

    24

    290*290

    *685

    23

    XXHA-

    P2505

    130-

    250

    >2.5

    1.0*5.0

    34

    330*330

    *750

    35

    XXHA-

    P3005

    150-

    300

    >3.0

    1.0*6.0

    40

    340*340

    *850

    41

    XXHA-

    P3505

    200-

    350

    >3.5

    1.0*6.0

    50

    340*340

    *850

    42

     

    Ceramic tube

    directional

     40°

    XXG-

    P1605

    60-

    160

    >1.5

    1.5*1.5

    20

    230*200

    *570

    14

    XXG-

    P2005

    80-

    200

    >2.0

    1.5*1.5

    29

    290*290

    *620

    26

    XXG-

    P2505

    130-

    250

    >2.5

    2.0*2.0

    39

    330*330

    *710

    32

    XXG-

    P3005

    150-

    300

    >3.0

    2.5*2.5

    49

    340*340

    *850

    37

    XXG-

    P3505

    200-

    350

    >3.5

    2.5*2.5

    59

    330*330

    *670

    38

     

    Tube Current

    5mA

    Power Supply

    AC220V ±10%  50HZ

    Controller Size (mm)

    367×320×164

    Controller

    Weight  (kg)

    13kg

    Insulating Material

    SF6 gas

    Working

     Temperature

    -25°~ +40°

    Relative Humidity

    ≤85%

     

    Standard  

    Condition

    Focus : 600mm

     Time of exposure :5min

    Film :Kodak brand film, double-sided lead film

    Film Developing : temperature ±2℃,

    developing 5min ,Density ≥2.0

      Safe Pressure

    0.35-0.50 MPa(Prohibition of use when it is lower than 0.35 MPa)

    5.Working principle description

    1. The controller using Silicon controlled rectifier bridge single-phase electric appliances,

    the rectified voltage is smoothed by the LC filter circuit into a DC voltage. The voltage of the

    thyristor chopper circuit into a variable frequency pulse in one direction, to give high-voltage

    pulse transformer as the X-ray generator power supply.Milliamps (mA) units can change

    unidirectional pulse frequency with the increase or decrease of x ray tube heating voltage,

    to ensure the stability of X-ray tube current.Kilovolt (kV) control unit can continuously control

    the tube voltage level to meet the requirements of different materials radiography.

    Anti-jamming loop Enhanced the control system ability to against high-voltage shock from

    the X-ray generator.

    2. X-ray generator adopts prevents shock type. X-ray tube anode grounded, and has

    over-temperature protection device. Once the temperature is excessively high, the contr-

    oller can automatically cut off the pressure, to prevent X-ray tube damage due to overheating.

    3. The power supply voltage fluctuations can be automatically adjusted by the controller itself,

    in order to get a stable X-ray. Exposure time and the state machine are controlled by asingle-chip

    micro-computer, pre-exposure time of up to 5 minutes.

    6 Accessory

    Spare Parts

    Quantity

    X-ray generator

    1

    Controller

    1

    Connecting cables

    1*25m

    Power cable

    1*10m

    Ground bat

    1*5m

    Fuse

    5

    Accessory kit

    1

     

     

     

    X-ray generator

    Controller

    Connecting cable

    (10 cores) 25m

    Power cable

    (2cores) 10m

    Instruction manual

    Earthing wire 5m

    Fuse    5PCS

    Accessories bag

Send message
%{tishi_zhanwei}%