PRODUCTS

COR Series High Accuracy Contracer
+
  • COR Series High Accuracy Contracer

COR Series High Accuracy Contracer

subcategory

  • Product description
  • Specifications
  • COR Series High Accuracy Contracer

    Main Function:

    It is suitable for measuring the linear contour of various precise mechanical work pieces, as angle analysis (Coordinates angle, line-line angle), Arc analysis(Radius, Center-center distance,  Center-line distance, Intersect-center distance, etc.), Straightness, groove depth, groove width, distance of groove edge, distance of groove center, horizontal distance etc.

     

    Main Feature:

    ---Z1: High accuracy and resolution digital grating sensors and precision bearing, directly read data to reduce the error generated by the measuring mechanism.

    Physical limit device to ensure the sensor always keep in the measuring range.

    Precision motor for sensor auto rising and landing.

    ---X: 0.1μm linear scale: full range of high precision measurement.

    ---High precision requirement work piece, ie.

    Peach shape bearing, double-groove bearing (Their common problem is the consistency of up/down hill measurement largely effect on the center distance).

    Curvature Ra. Of very small arc measurement(central angle less than 30°),.

    ---Fast and convenient measurement for the datum requirement work piece, ie. Thread parameters, angle, and profile.

    ---High quality industrial automation computer and printer for data acquisition, processing and printing.

    ---Safe control and measurement: Can stop the tester anytime during measurement and moving.

     

    High Accuracy: Error of Curvature Ra.:±1μm

    Error of Angle: ±1′

    Deviation of Groove Shape: ±0.3μm

    Good Reproducibility:Regardless the work piece loading position, or changing the measuring direction, the consistence of its curvature Ra.: ± 1μm

    Good Repeatability:Curvature Ra.:±0.3μm

    Angle:± 0.5′

    Wide measuring range: Z1: 40-60mm, X max.:320mm

    High cost performance:

    Stability: Air floating structure, never wear (10 years precision constant by normal using).

    Measurement data can be imported CAD analysis, realize seamless link

    Zoom freedom

    Perfect fixtures for work piece fixing, adjusting and fast measuring.

     

    Digital Sensor:

    Accuracy kept in  0.05μm in full range, with the balanced lever rod, that can measure in any orientation.

    Main Feature:

    High accuracy: Resolution: 0.05μm,without artificial read error

    Wide measuring range: Z1: 60mm, X: 320mm

    Automation: Probe rising and landing by the linear motor,

    High anti-interference ability: Digital signal, more stable, high precision in full range.

     

    COR Software:

    windows based measuring program, graphic interface, more functional. ,

    Friendly user interface, ICONS clear, the definition of measurement point and datum line is simple, and easy to operate.

    Powerful error compensation capability, measurement result more accuracy

    Numbers of different assessed methods, to satisfy specific requirement.

    Freedom zoom

    Measurement data can be imported CAD analysis, realize seamless link

    Key words:
    • COR Series High Accuracy Contracer
  • Main Parameters:

    Model No.

    COR100C

    COR100B

    COR150

    COR220

    Measuring

    Range

    X

    (Guiderail)

    100mm

    100mm

    150mm

    220mm

     

    Z1(Probe)

    40mm

    50mm

    50mm

    60mm

     

    Z(Column)

    400mm

    400mm

    500mm

    500mm

    X(L=Xmoving distance)

    ±(1.5+L

    /300) μm

    ±(1.2+L

    /300) μm

    ±(1+L

    /300)μm

    ±(1+L

    /300) μm

    Z1(H=Z1

    measuring height)

    ±(1.2+10H

    /100)μm

    ±(1+8H

    /100) μm

    ±(0.8+6H

    /100) μm

    ±(0.8+6H

    /100) μm

    RMeasuring

    Range

    R≤10mm

    ±1.2μm

    ±1.0μm

     

    10≤R≤25

    ±1.2+

    (R/12)μm

    ±1.0+

    (R/12)μm

     

    25≤R≤300

    ±1.2+

    (R/8)μm

    ±1.0+

    (R/8)μm

     

    300≤R

    ±1.2+

    (R/4)μm

    ±1.0+

    (R/4)μm

    XHorizontal Arm

    Straightness

    0.2μm

    /60mm

    0.15μm

    /60mm

     

    Scale

    resolution

    0.1μm

    0.1μm

     

    Origin

    Imported

    Z1 Probe

    Resolution

    0.05μm

     

    Type

    Inductive

     

    Origin

    Imported

     

    Moving direction

    Forward/backward

    bidirectional

     

    Measuring force

    0.5-6g

     

    Stylus tip

    Hard alloy R:0.05mm、

    0.01mm

     

    Climbing angle

    Go up 77°,

    Go down 88°

    Speed

    Measuring

    0.02mm/S~4mm/s

     

    Positioning

    0.02mm/S~4mm/s

    Zoom

    Any

    Turning Stage

    X:±30°,Y:±7.5mm,

    Z:360°(with fine tuning)

    Installation

    Requirement

    Power

    Supply

    20-240V AC, 50HZ,

    Separated grounding;

    Max. consumed450W

     

    Compressed

    Air

    Pure compressed air:Pressure0.4MP,

    Consumed 0.1m³ /min (air supply0.6MP,

    0.25m³ /min more)

     

    Environment

    Working Temperature:10°-30°(room);

    Humidity 20-80%RH(no condensation),

    Well grounding, no obvious vibration

     