PRODUCTS

Portable Leeb Hardness Tester
Portable Leeb Hardness Tester
+
  • Portable Leeb Hardness Tester
  • Portable Leeb Hardness Tester

Portable Leeb Hardness Tester

subcategory

  • Product description
  • Specifications
  • Portable Leeb Hardness Tester Hardy 

    The Hardy P150 measures the hardness of a large number of materials in various hardness units. Seven types

    of impact devices make this possible. It is equipped with a USB/RS232-cable for PC transfer.

    Measuring Features    

    Wide measuring range with Leeb hardness testing principle

    6 hardness units

    Large memory capacity with information about number of group, date, average value, impact device, impact times,material for every measured value

    Upper and lower limit can be preset. It will alarm automatically

    when the measured value exceeds the limit.

    Test at any angle, even upside down

    User calibration function

    7 types of impact devices for specific applications optional

    Automatic identification by connection

    Large LCD-display: all functions and parameters are displayed + backlight

    PC-transfer with cable (both USB and RS232 interface) and software

    Battery capacity display - 100 hours operating time (without backlight)

    Auto power off (after 5 minutes) to save energy

    Measurements on steel, cast steel, cold work tool steel,stainless steel, gray cast iron, nodular cast iron, cast aluminium alloys, brass, bronze and wrought copper alloys Measurements on large and small hollows, bearings, heavy parts, permanently assembled parts

    Defect analysis of pressure vessels, steam generators, etc.

    Material identification of metal warehouses

  • Technical specifications:    

    Hardness units:

    HL (Leeb), HB (Brinell), HRB (Rockwell B),

    HRC (Rockwell C), HV (Vickers), HS (Shore D)

    Measuring range:

    170 - 960 HLD

    Measuring direction:

    360°

    Standard impact device:

    D

    Memory size:

    48-600 groups (relative to number of impact impact times 1-32)

    Statistics:

    Number of group, date, average value, impact device, impact

    times, material, measured values

    Setting of limits:

    Acoustic signal by overstepping preset min. und max. limits

    Minimum weight of sample:  

    > 5kg solid material;

    2-5kg on stable surface;

    < 2kg with coupling paste on stable surface

    Memory function:

    Manually or automatically

    Data transfer:

    Cable (both USB and RS232-connection) und software

    Languages device and manual:

    English

    Display:

    128 × 64 Dot-Matrix-LCD

    Backlight :

    ON / OFF key

    Battery capacity:

    100 hours (without backlight)

    Auto Power Off :

    After 5 minutes

    Power supply :

    2 x 1,5 Volt-AA-batteries

    Relative humidity:

    ≤ 90%

    Working temperature:

    -10°C to +40°C

    Weight :

    380 g (with batteries)

    Size :

    125 x 67 x 30mm

     

Send message