PRODUCTS

HP Digital Force Gauge
+
  • HP Digital Force Gauge

HP Digital Force Gauge

subcategory

  • Product description
  • Specifications
  • HP Digital Force Gauge

    Features

    1. 2.8-inch TFT true color display;

    2. Built-in real time clock, display real time and date;

    3. Peak values, real-time values, and test curves can be displayed on the same screen;

        enabling procedural monitor and reproduction of the test.

    4. Upper/lower offset; selection of alarm for not excess of limit, and alarm for excess of  limit.

    5. When alarm values are exceeded, the buzzer acts while the display shows alarm information,

        optional relay output, when use relay output ports, connect the power adapter first to prevent

        automatic shutdown.

    6. Direction buttons and display can be rotated 180°

    7. Enable automatic unit conversion: N, kg, and lb; pressure unit Mpa can be converted as well.

    8. Peaks can be held or cleared; clearing time can be set.

    9. A maximum of 100 groups of test reports can be saved permanently. The saved content

         includes test time, peak, and average valley. One group of test curves can be saved as well for

         reproducing the test procedure.

    10. Material strength can be calculated based on sectional area input.

    11. Shutdown and backlight can be set to perform automatically.

    12. Pictures and literary descriptions make various operations easy to understand and learn.

    13. Relying on the PC dedicated test software, the force gauge can realize unlimited storage,

          transmission, and reproduction of test curve data.(Coming soon).

    14. Mini printer can print the test results(recommended to choose Rongda RD series

          micro-printer).

    15. Installed on different test benches, the force gauge can implement various tests.

  • Specifications and Parameters (for Embedded Products).

     

    Model

    HP-2N

    HP-5N

    HP-10N

    HP-20N

    HP-50N

    HP-100N

    HP-200N

    HP-500N

    Range

    2N

    5N

    10N

    20N

    50N

    100N

    200N

    500N

    Calibration

    0.001N

    0.001N

    0.005N

    0.01N

    0.01N

    0.05N

    0.1N

    0.1N

    Calibration of Pressure

    0.01Mpa

    0.1Mpa

    1Mpa

    Sensor

    Embedded sensor

    Measuring Range

    1%~100% F.S

    Indication Error

    ±0.5% F.S

    Units

    N、kg、lb

    Display

    2.8-inch true color

    Working Temperature

    20±10℃

    Relative Humidity

    15%~80%RH

    Working Conditions

    No vibration sources or corrosive materials exist.

    Weight

    1kg

     

     

      Specifications and Parameters (for External Products)

     

    Indication Error

    Measuring

    Range

    Sense

    Calibration

    Range

    Model

    ±1% F.S (depending on the sensor configured)

    1%~100% F.S

    External S-shaped sensor

    0.5N

    1000N

    HP-1K

    1N

    2000N

    HP-2K

    1N

    5000N

    HP-5K

    0.005kN

    10kN

    HP-10K

    0.01kN

    20kN

    HP-20K

    0.01kN

    50kN

    HP-50K

    0.05kN

    100kN

    HP-100K

    External spoke

    sensor

    0.1kN

    200kN

    HP-200K

    0.1kN

    500kN

    HP-500K

    0.5kN

    1000kN

    HP-1000K

    1kN

    2000kN

    HP-2000K

     

      Buttons and Their Functions

     

    Buttons

    Usage and Role Description

    Power

    Power, Turn on or turn off ;

    Confirm\OK

    Confirm the present operation or enter into present menu ;

    Increase the cursor value or choose parameter in upper column

    Decrease the cursor value of choose parameter in lower column

    Move the cursor to the left  ;

    Move the cursor to the right ;

    Print

    Printing test data or capture report

    Return(escape)

    Cancel present operation or escape present menu ;

    Curve Capture

    Enter into curve capture mode, the instrument automatically start recording the testing process, after the completion of the test results and test curves can be saved as well for reproducing the test procedure.

    Report check

    Check the test report stored in the instruments  ;

    Zero

    Zero the test force value

    Peak value clear

    Manual clear the present peak value 

     
     
Send message
%{tishi_zhanwei}%