PRODUCTS

EP Digital Force Gauge
EP Digital Force Gauge
EP Digital Force Gauge
EP Digital Force Gauge
EP Digital Force Gauge
EP Digital Force Gauge
EP Digital Force Gauge
EP Digital Force Gauge
EP Digital Force Gauge
EP Digital Force Gauge
+
  • EP Digital Force Gauge
  • EP Digital Force Gauge
  • EP Digital Force Gauge
  • EP Digital Force Gauge
  • EP Digital Force Gauge
  • EP Digital Force Gauge
  • EP Digital Force Gauge
  • EP Digital Force Gauge
  • EP Digital Force Gauge
  • EP Digital Force Gauge

EP Digital Force Gauge

subcategory

  • Product description
  • Specifications
  • EP Digital Force Gauge

    1. LCD double digital display with backlight;

    2. USB interface; hot swappable.

    3. Free setting of fracture alarm value, and upper/lower offset; selection of fracture alarm, alarm for not excess of limit, and alarm for excess of limit. When alarm values are exceeded, the buzzer acts while the display shows alarm information. The two SC open-collector level outputs drive the DC 12V relay or the solenoid to act, each output being 50mA. To use output ports, connect the power adapter first.

    4. Display can be rotated 180°.

    5. Enable automatic unit conversion: N, kgf, and lbf.

    6. Peaks can be held or cleared; clearing time can be set.

    7. A maximum of 10 groups of test reports can be saved permanently. The saved content includes peak, and average valley.

    8. Shutdown and backlight can be set to perform automatically.

    9. Relying on the PC dedicated test software, the force gauge can realize unlimited storage, transmission, and reproduction of test curve data.

    10. Installed on different test benches, the force gauge can implement various tests.

  • Specifications and Parameters (for Embedded Products).

     

    Model

    EP-2N

    EP-5N

    EP-10N

    EP-20N

    EP-50N

    EP-100N

    EP-200N

    EP-500N

    Range

    2N

    5N

    10N

    20N

    50N

    100N

    200N

    500N

    Calibration

    0.001N

    0.001N

    0.005N

    0.01N

    0.01N

    0.05N

    0.1N

    0.1N

    Calibration of Pressure

    0.01Mpa

    0.1Mpa

    1Mpa

    Sensor

    Embedded sensor

    Measuring Range

    1%~100% F.S

    Indication Error

    ±0.5% F.S

    Units

    N、kg、lb

    Display

    LCD

    Working Temperature

    20±10℃

    Relative Humidity

    15%~80%RH

    Working Conditions

    No vibration sources or corrosive materials exist.

    Weight

    1kg

     

     

      Specifications and Parameters (for External Products)

     

    Indication Error

    Measuring  Range

    Sense

    Calibration

    Range

    Model

    ±1% F.S (depending on the sensor configured)

    1%~100% F.S

    External S-shaped sensor

    0.5N

    1000N

    EP-1K

    1N

    2000N

    EP-2K

    1N

    5000N

    EP-5K

    0.005kN

    10kN

    EP-10K

    0.01kN

    20kN

    EP-20K

    0.01kN

    50kN

    EP-50K

    0.05kN

    100kN

    EP-100K

    External spoke

    sensor

    0.1kN

    200kN

    EP-200K

    0.1kN

    500kN

    EP-500K

    0.5kN

    1000kN

    EP-1000K

    1kN

    2000kN

    EP-2000K

       

         Interfaces and Their Functions

          1. Number of Peak saved;

          2. The values Meaning of the Peak window shows:

    a) PEAK:Manual Peak Clear;

    b) PEAK  ATUO:Automatic peak Clear;

    c) PEAK  AVER:Average peak of the Saved peak data group;

    d) PEAK  MAX: maximum peak of the Saved peak data group;

    e) PEAK  MIN:minimum peak of the Saved peak data group;

          3. Display the peak value hold and real time value;

          4. Battery icon;

          5. The online with computer software symbol;

          6. Measuring unit;

          7. Push(compression) sign;

          8. Pull(tension) sign;

          9. Alarm indicator:

    a) “—”the display value is less than the lower force limit;

    b) “○”Be tested or Fracture, end the test;

    c) “+”the display value is greater than the upper force limit;

     

    Buttons and Their Functions

     

    Button

    Standalone Test Mode

    Online Test Mode

    Storage & Query Mode

    Menu Operation Mode

          

    Shutdown

    Shutdown

    Invalid

    Invalid

          

    Unit conversion

    Invalid

    Exit

    Quit parameter modification or exit

          

    Zero set

    Zero set

    Clear peak value of flashing number

    Data cleared

      

    Test output

    Invalid

    output peak value test report

     

    Up

      

    Enter storage & query mode

    Invalid

    Switch to upper window

    Down

         

    Enter parameter setting mode

    Invalid

    Invalid

    Confirm parameter modification

       

    Peak value saved

    Peak value saved

    Move the blinking number leftward by one unit

              

    Peak clearing

    Peak clearing

    Move the blinking number rightward by one unit

     

Send message
%{tishi_zhanwei}%