• Granite

    Granite

  • OUR COMPANY

    OUR COMPANY

  • OUR COMPANY

    OUR COMPANY

  • OUR COMPANY

    OUR COMPANY

  • OUR COMPANY

    OUR COMPANY

  • OUR COMPANY

    OUR COMPANY

  • OUR COMPANY

    OUR COMPANY

Wechat: 8613620227427

Msn: joerogertools@hotmail.com

Skype: joeroger

Email : sales@prideinstrument.com

    info@prideinstrument.com

COPYRIGHT SHENZHEN PRIDE INSTRUMENT INC. ALL RIGHTS RESERVED   粤ICP备14010292号

Technical Support:300.cn

PRODUCTS

EP Digital Force Gauge

Serial number
EP-2N
没有此类产品
immediate inquiry
Product description
Specifications

EP Digital Force Gauge

1. LCD double digital display with backlight;

2. USB interface; hot swappable.

3. Free setting of fracture alarm value, and upper/lower offset; selection of fracture alarm, alarm for not excess of limit, and alarm for excess of limit. When alarm values are exceeded, the buzzer acts while the display shows alarm information. The two SC open-collector level outputs drive the DC 12V relay or the solenoid to act, each output being 50mA. To use output ports, connect the power adapter first.

4. Display can be rotated 180°.

5. Enable automatic unit conversion: N, kgf, and lbf.

6. Peaks can be held or cleared; clearing time can be set.

7. A maximum of 10 groups of test reports can be saved permanently. The saved content includes peak, and average valley.

8. Shutdown and backlight can be set to perform automatically.

9. Relying on the PC dedicated test software, the force gauge can realize unlimited storage, transmission, and reproduction of test curve data.

10. Installed on different test benches, the force gauge can implement various tests.

Corresponding parameter set not found, please add it in property template of background

Specifications and Parameters (for Embedded Products).

 

Model

EP-2N

EP-5N

EP-10N

EP-20N

EP-50N

EP-100N

EP-200N

EP-500N

Range

2N

5N

10N

20N

50N

100N

200N

500N

Calibration

0.001N

0.001N

0.005N

0.01N

0.01N

0.05N

0.1N

0.1N

Calibration of Pressure

0.01Mpa

0.1Mpa

1Mpa

Sensor

Embedded sensor

Measuring Range

1%~100% F.S

Indication Error

±0.5% F.S

Units

N、kg、lb

Display

LCD

Working Temperature

20±10℃

Relative Humidity

15%~80%RH

Working Conditions

No vibration sources or corrosive materials exist.

Weight

1kg

 

 

  Specifications and Parameters (for External Products)

 

Indication Error

Measuring  Range

Sense

Calibration

Range

Model

±1% F.S (depending on the sensor configured)

1%~100% F.S

External S-shaped sensor

0.5N

1000N

EP-1K

1N

2000N

EP-2K

1N

5000N

EP-5K

0.005kN

10kN

EP-10K

0.01kN

20kN

EP-20K

0.01kN

50kN

EP-50K

0.05kN

100kN

EP-100K

External spoke

sensor

0.1kN

200kN

EP-200K

0.1kN

500kN

EP-500K

0.5kN

1000kN

EP-1000K

1kN

2000kN

EP-2000K

   

     Interfaces and Their Functions

      1. Number of Peak saved;

      2. The values Meaning of the Peak window shows:

a) PEAK:Manual Peak Clear;

b) PEAK  ATUO:Automatic peak Clear;

c) PEAK  AVER:Average peak of the Saved peak data group;

d) PEAK  MAX: maximum peak of the Saved peak data group;

e) PEAK  MIN:minimum peak of the Saved peak data group;

      3. Display the peak value hold and real time value;

      4. Battery icon;

      5. The online with computer software symbol;

      6. Measuring unit;

      7. Push(compression) sign;

      8. Pull(tension) sign;

      9. Alarm indicator:

a) “—”the display value is less than the lower force limit;

b) “○”Be tested or Fracture, end the test;

c) “+”the display value is greater than the upper force limit;

 

Buttons and Their Functions

 

Button

Standalone Test Mode

Online Test Mode

Storage & Query Mode

Menu Operation Mode

      

Shutdown

Shutdown

Invalid

Invalid

      

Unit conversion

Invalid

Exit

Quit parameter modification or exit

      

Zero set

Zero set

Clear peak value of flashing number

Data cleared

  

Test output

Invalid

output peak value test report

 

Up

  

Enter storage & query mode

Invalid

Switch to upper window

Down

     

Enter parameter setting mode

Invalid

Invalid

Confirm parameter modification

   

Peak value saved

Peak value saved

Move the blinking number leftward by one unit

          

Peak clearing

Peak clearing

Move the blinking number rightward by one unit

 

暂未实现,敬请期待
暂未实现,敬请期待
Previous article
Next article