PRODUCTS CENTER
Ireland Coating Thickness Gauge
Category:
Product Description
Coating Thickness Gauge
Features:
●Two thickness measuring methods adopted, the gauge can be applied to thickness measuring of non-magnetic coating on magnetic metal substrate as well as non-conductive coating on non-magnetic metal substrate;
●5 types of probes can be used (F400, F1, F10, N1, CN02,);
●2 measuring modes are available: continuing measuring mode(CONTINUE)and single measuring mode(SINGLE);
●2 operation modes are available: direct mode (DIRECT) and batch mode (A-B);
●5 statistic values:mean value(MEAN), max. value(MAX), min. value(MIN), numbers of measuring(NO.), standard deviation(S.DEV);
●2 methods can be used to calibrate the gauge, and the system error of the probe can be corrected by use of basic calibrating method:
●Storage function: 495 measuring values can be stored;
●Deletion function: delete the single questionable data occurring in measuring, as well as all of the data in memory area to perform the new measuring;
●Limit can be set: capable of alarming automatically for measuring values out of limit; and a batch of measuring values can be analyzed via histogram;
●Printing function: measuring value, statistic value, limit and histogram can be printed;
●Capable of communication with PC: measuring values and statistic values can be sent to PC to perform the further process for data;
●Indication of low voltage;
●Buzzing indication in the course of operation;
●With the function of error warning, error warning can be carried out through display or buzzing;
●Two shut down modes are available: manual shut down mode and automatic shut down mode;
INTERNATIONAL STANDARDS:
ASTM B 499, ASTM D 1400, BS 3900-C5-6B, DIN 50981,DIN 50984, ISO 1461,ISO 2360
Technical parameters
|
Probe model |
F400 |
F1 |
F1/90° |
F5 |
F10 |
|||
|
Operating principle |
Magnetic induction |
|||||||
|
Measuring range (mm) |
0~400 |
0~1250 |
0~5000 |
0~10000 |
||||
|
Low range resolution(mm) |
0.1 |
0.1 |
1 |
10 |
||||
|
Accuracy |
One-point calibration (mm) |
±(3%H+1) |
±(3%H+5) |
±(3%H+10) |
||||
|
Two-point calibration (mm) |
±((1~3)%H+0.7) |
±((1~3)%H+1) |
±((1~3)%H+5) |
±((1~3)%H+10) |
||||
|
Measuring conditions |
Min curvature radius (mm) |
Convex |
1 |
1.5 |
Flatten |
5 |
10 |
|
|
Diameter of the min area (mm) |
F3 |
F7 |
F7 |
F20 |
F40 |
|||
|
Probe model |
N400 |
N1 |
N1/90° |
CN02 |
N10 |
||||
|
Operating principle |
Eddy current |
||||||||
|
Measuring range (mm) |
(Chrome on copper
|
0~1250 0~40) |
10~200 |
0~10000 |
|||||
|
Low range resolution(mm) |
0.1 |
0.1 |
1 |
10 |
|||||
|
Accuracy |
One-point calibration (mm) |
±(3%H+0.7) |
±(3%H+1.5) |
±(3%H+1) |
±(3%H+25) |
||||
|
Two-point calibration (mm) |
±[(1~3)%H+0.7] |
±[(1~3)%H+1.5] |
___ |
±[(1~3)%H+25] |
|||||
|
Measuring conditions |
Min curvature radius (mm) |
Convex |
1.5 |
3 |
Flatten |
Only flatten |
25 |
||
|
Diameter of the min area (mm) |
F4 |
F5 |
F5 |
F7 |
F50 |
||||
|
Critical thickness of substrate (mm) |
0.3 |
0.3 |
0.3 |
No limit |
50mm aluminum foil |
||||
Note: H——Nominal value